08
Adequate hand washing facilities supplied & accessible
Priority Foundation-5-202.12 (A), Pf: Handwashing Sinks, Installation; Proper Temperature, Mixing Faucet. No hot water available at only handwashing sink in kitchen. Per Person in Charge (PIC), hot water at sink was shut off due to a leak. Water of 100°F must be available through a mixing valve or combination faucet at all handwashing sinks. PIC turned hot water on at sink and correct temperature was achieved for proper handwashing. Discussed importance of hot water availability for proper handwashing with PIC. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you. https://www.maricopa.gov/4573/AMC-Toolbox---Handwashing.
Corrected At Time Of Inspection
20
Proper cold holding temperatures
PRIORITY VIOLATION-3-501.16(A)(2) and (B), P: Time/Temperature Control for Safety Food, Cold Holding. At reach-in refrigerator, across from stove, observed various TCS (time/temperature controlled for safety) foods such as cut tomatoes, cut lettuces, deli ham, shredded cheeses, dressings and raw chicken with internal temperatures between 51-56*F. Except during preparation, cooking, cooling, or when time is used as a control all TCS food to be maintained at 41°F or less. Ambient temperature of reach-in was 51.2*F and 56.3*F when measured with inspector min/max thermometer. Per Person in Charge (PIC) food was placed in reach-in approximately 2:00pm (less than 4 hours). PIC moved all TCS foods to walk-in to rapidly cool to 41*F or below. Discussed, with PIC, importance of maintaining TCS foods at 41*F or below. PIC contacted repair service for reach-in. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you. https://www.maricopa.gov/4576/AMC-Toolbox---Cold-Holding.
Corrected At Time Of Inspection
31
Proper cooling methods used; adequate equipment for temperature control
Priority Foundation-4-301.11, Pf: Cooling, Heating, and Holding Capacities-Equipment. Observed reach-in refrigerator, across from stove, with ambient temperatures of 51.2*F and 56.3*F when measured with inspector min/max thermometer. Establishment shall have enough cold holding facilities, to maintain TCS foods at 41*F or below, for their operations. All TCS foods were removed from reach-in. Person in Charge (PIC) contacted repair service for reach-in. Discussed with PIC importance of monitoring temperatures for all cold holding units. For a permanent fix to this violation, check out these simple tools in our Active Managerial Control Toolbox, made especially for you. https://www.maricopa.gov/4617/AMC-Toolbox---Cooling.
Correct Prior To Reinspection