NA means not available. See detailed inspection reports for additional information.
OC Re-Inspection - E&D Class 4 This inspection was conducted with the owner. A PDF copy of this inspection report was emailed to Marinar Y. at the time of this inspection. Correct the following prior to final permit approval and re-inspection scheduled for 12/07/2021; 1. The drain valves beneath far right compartment of the the 4-compartment sink is leaking. Repair the leak in this drain valve of the 4 Compartment sink. 2. A soda fountain has been added without adequate backflow protection. Use the disconnected RPZ backflow prevention device to provide backflow protection for the water supply line to the soda fountain carbonator. All piping and fittings on the downstream side of this device must be plastic or stainless steel, no copper or brass. Also, provide a funnel drain assembly that empties into a floor sink with a minimum 1 in. air-gap for this device. 3. Provide smooth, non-absorbent, easily cleanable covers above the walk-in refrigerator as discussed. There are currently acoustical ceiling tiles with the exposed acoustical surfaces installed above the walk-in refrigerator. 4. Repair the cold water valve on the hand sink in the back kitchen area. 5. Replace the missing floor grates on the floor sinks throughout the facility. No county legal action will result from this inspection.