Rancho De Los Caballeros
Permit ID: FD-83896
Permit Type: E & D
1551 S Vulture Mine Rd Wickenburg 85390
NA means not available. See detailed inspection reports for additional information.
OC Inspection - E&D Class 3 - Palo Verde Complex This inspection was conducted with the facility manager. A pdf copy of this inspection report was emailed to Dan L. at the time of this inspection. No county legal action will result form this inspection. This facility is not currently in operation. The following items must be addressed prior to final permit approval; 1. Provide waterproof material such as FRP on the walls behind, around and underneath the mechanical dishwasher, three compartment sink and food prep sink where there is currently painted drywall. Use FRP adhesive. Do not use nails or screws. 2. Provide a separate, indirect drain pipe to a floor sink with a minimum 1 in. air-gap for the three compartment sink that currently has a direct connection. 3. Repair all leaking drain pipes at all sinks where necessary. 4. Provide new, 1022 backflow prevention devices for all coffee and tea machines connected to water supply lines. 5. Waterproof material such as FRP must be installed behind and underneath the mop sink. 6. Provide waterproof material such as epoxy to the laminate beverage station countertops. 7. All new countertops must be solid surface material such as stainless steel or granite. Do not install laminate countertops. 8. All chemical dispensers installed on water lines must have proper air-gaps.