Rusty Taco
Permit ID: FD-84698
Permit Type: E & D
205 E 7th St Tempe 85281
NA means not available. See detailed inspection reports for additional information.
Construction inspection for a Class 4 E&D 10+ permit was conducted by appointment with GC Andy. Inspection rights were delivered to Heath F. via email. The project is approximately 85% complete. The facility will be conducting IPM/AMC. The IPM plan for the facility is still being updated. The IPM will be finalized and reviewed on-site and is required for final permit approval. Please ensure the following items are addressed by the completion of the project: 1) Provide rigid piping for the flex drain lines at the 1022 backflow preventers and provide 1" minimum air gaps above the floor sink. The bar drink rails must also be rigid piped and air gapped to floor sinks. 2) Provide a splash guard to the left side of the handwash sink located at the bar. 3) Provide a semi-gloss finish to the soda fountain area and restroom walls. 4) Caulk-in all plumbing penetrations and escutcheon plates throughout the facility with silicone. At the final construction inspection, ensure hot water measuring 120' F minimum is provided to the plumbing system and all refrigerators are on and measuring at 41' F or below. Please contact the Department to schedule the final construction inspection (100% completion with Certificate of Occupancy) at 602.506.6824. MCESD inspection report was delivered via email. No County legal action will result from this inspection.