PT Pho Express 2
Permit ID: FD-87155
Permit Type: E & D
23425 N 39th Dr Suite 106 Glendale 85310
NA means not available. See detailed inspection reports for additional information.
Construction Inspection - E&D Class 4 This inspection was conducted with the on site contractor. A PDF copy of this inspection report was emailed to Jose R. at the time of this inspection. Correct the following prior to final permit approval; 1. Handwashing sinks must be centrally located, visible, and directly accessible within 25-feet of all food/beverage preparation, food/beverage dispensing and ware washing and similar workstation areas. Provide an additional, dedicated hand sink with side splashes in the main cooking area. 2. Do not use the mop sink faucet. Y- Valves and downstream shut-off devices are not permitted on mop sink faucets or chemical dispensers. 3. Finish installing and attaching the new food prep sink to the wall. 4. All refrigerated food equipment, including the walk-in units must be running and able to maintain foods at 41°F or less. 5. Provide a metal cove finish at the floor/wall junctures on the inside and exposed outside portions of the walk-in refrigerator. 6. Provide a cove base finish at all floor/wall junctures throughout the front service area and restrooms. 7. Provide a certified, RPZ backflow prevention device for the water supply to the soda fountain carbonator. All piping and fittings on the downstream side of this device must be plastic or stainless steel, no copper or brass. No county legal action will result from this inspection.